Cooling tower components – coolers

Cooling tower components – coolers

Short Description:


Product Detail

Product Tags

Cooler

The cooling coil design ensures higher operating power. The design of double-row tubes makes the arrangement of tubes compact, while reducing the resistance to air flow. The coil is inclined along the flow direction of circulating medium, meanwhile, there is an air inlet valve at the inlet of circulating medium and a drainage valve at the outlet of circulating medium; when the equipment is shut down, the air inlet and drainage valves are opened and the circulating medium is discharged automatically. Successfully solved the common problem of freezing and cracking of the coils in winter, which plagued the peer manufacturers.
The design pressure of the cooling coil is 0.8MPa, and the coil is welded and assembled in water by 1.0MPa gas tightness test to ensure no leakage.

details (3)

Anti-freeze stainless steel cooler

details (2)

Anti-freeze type copper tube cooler

Anti-freezing instructions

Existing closed cooling tower heat exchanger coils are designed parallel to the horizontal plane, taking into account the heat transfer effect, heat exchanger coils are relatively thin, the temperature is lower than 0 ℃, the need to empty the internal liquid to achieve antifreeze effect, the cooler because of the local hydraulic loss is too large, that is, the use of air compressors repeatedly blow can not exhaust the internal liquid, heat exchanger coils single tube internal as long as a section filled with liquid, it will freeze, resulting in coils Rupture, the later repair is very troublesome.

Some customers can only use antifreeze, adding antifreeze to the whole piping system to achieve the effect of antifreeze, industry, generally used as antifreeze for glycol, but glycol is easy to volatilize, so every winter piping system should be added, which increases the high additional operating costs.

detail

The tilted anti-freeze heat exchanger coils developed by our company can completely solve this problem. When the equipment stops using, just open the upper exhaust valve and drain the lower drain valve to empty the liquid inside the coils smoothly and achieve the anti-freeze effect. So compared to other companies' closed cooling tower heat exchanger coils, our tilted anti-freeze heat exchanger coils have the following advantages.
1. significant anti-freeze effect, fundamentally and completely solve the persistent problem of heat exchanger coils being frozen.
2. anti-freeze measures are easy to operate and save time.
3. The cost of anti-freeze is almost zero, no need to add anti-freeze liquid, no need to add electric heater, that is, save the material and reduce energy consumption.